Installation Requirement

1. INSTALLATION ENVIRONMENT: Install the lift in a dry place with normal temperatures , keep the location in warm place with normal temperatures , keep the location in warm place with normal temperatures , keep the location in warm place with normal temperatures

2. CONCRETE: Concrete must be a thickness of 4'' minimum and without reinforcing steel bars, and must be dried totally before installation; Concrete must be in good condition and must be of test strength 3,000psi (200kg/cm2) minimum; Floors must be level with no cracks; Make sure there is enough space for the model installation.

3. POWER SUPPLY: The electrical source must be 2.2KW minimum. The source cable size must be 2.5mm2 and in good condition where contacting with the floor.

4. AIR SUPPLY: Air pressure requirement: 72psi~116psi, Air line size ¢8×¢6 and ¢6×¢4.